Wellness and safety in a single ceiling light

SIDèReA bkl

CEILING LIGHT BACTERIAL KILLER

A SINGLE DEVICE TO GUARANTEE LIGHT QUALITY AND PROTECTION FROM VIRUSES, BACTERIA, AND SARS-COV-2

Always committed to improving light performance and the well-being of operators and their users, FARO has developed Sidèrea BKL the ceiling light that, thanks to the near-UVA LED technology, also becomes a disinfection device for the work environment.

FARO CELING LIGHT SIDEREA BKL

Disinfecting and reducing bacteria and Sars-Cov-2 with near-uva LED light

The lighting technology features are integrated with the near-UVA beam disinfection function, thus transforming the ceiling light into an instrument to prevent and reduce the risk of cross-contamination from viruses and bacteria enclosed enviroments.
Disinfection of the working environment results in a guarantee for the health of medical staff and all users.-

Light spectrum for excellent contrast and detail vision

Entirely Made in Italy, Sidèrea BKL guarantees a more realistic solar spectrum lighting with double illuminant to offer a homogeneous and proportionate lighting avoiding both shadow areas and “cave” effect. Scientific Research has repeatedly confirmed not only how sunlight is the best and most realistic source of lighting but is itself a natural antibacterial.

Efficacy proven in the laboratory

In the Departments of Molecular Medicine and Development and Medical Biotechnology of the University of Siena Sidèrea BKL was tested on the SARS-COV-2 virus and on the Escherichia coli and Staphylococcus aureus bacteria.
Laboratory tests have shown that Sidèrea BKL allows up to 99.5% abatement of SARS-COV-2 present on surfaces.**

** Departement of Molecular and Developmental Medicine: EVALUATION OF VIRUCIDE ACTIVITY AGAINST SARS-COV-2 OF nUVA CEILING LAMP BY FARO – TEST ON nUVA-A CEILING LAMP BY FARO.

EFFICACY AGAINST STAPHYLOCOCCUS AUREUS
60 MIN
93%
120 MIN
97%
180 MIN
99%
EFFICACY AGAINST ESCHERICHIA COLI
180 MIN
90%
240 MIN
95%
300 MIN
99%
SARS-COV-2 REDUCTION*
15 MIN
87%
90 MIN**
97%
180 MIN**
99.5%

* Performed with a small system at double power.
**Equivalent minutes reported to the real system.

USE THE SIMULATOR TO CALCULATE THE PERCENTAGE OF REDUCTION
OF THE MICROBIOLOGICAL CHARGE AND THE APPLICATION TIME

Loading...

CHOOSE THE PERCENTAGE OF REDUCTION OF THE MICROBIOLOGICAL CHARGE:

85%

(DRAG THE SLIDER TO CHANGE THE % THE MICROBIOLOGICAL CHARGE)

TIME REQUIRED IN MINUTES:


AT 135 CM

min
min
min

AT 220 CM

min
min
min
Loading...

CHOOSE THE APPLICATION TIME AND VERIFY THE PERCENTAGE OF REDUCTION OF THE MICROBIOLOGICAL CHARGE:

15min

(DRAG THE SLIDER TO CHANGE THE APPLICATION TIME)

PERCENTAGE OF REDUCTION:


AT 135 CM

%
%
%

AT 220 CM:

%
%
%

Calculation based on the interpolation curve “Percentage Reduction Curve” The outcomes based on this simulation might be differ from experimental data

FOCUS

CHARACTERISTICS

Three dedicated cycles for the disinfection process

The intensity of the disinfection action which is performed through a homogeneous distribution of near-UVA rays, varies according to the exposure time and the extent of the surfaces to be treated.

Direct and indirect lighting

Multidirectional light for a homogeneous and proportionate illumination of the environment.

Custom Illumination

Adjustable light intensity according to the surgery conditions and operating time, thanks to the remote control with 5 light scenarios pre-configured by FARO and rewritable by the user.

VIDEO

SIDEREA BKL

PRODUCT SPECIFICATIONS

CHARACTERISTICS | DOWNLOAD

GENERAL SPECIFICATIONS
SUNLIGHT MODE
BKL MODE
POWER
max 200 W
max 300 W
DIMENSIONS
1.605 x 645 mm
WEIGHT
18 kg
LUX
up to LUX 2.200 (at a distance of 1,4 m)
n/a
COLOUR TEMPERATURES
6.500 K
n/a
TM30
Rf 97.3 | Rg 100.3
n/a
UGR
< 10
n/a
MEMORIZATION OF THE LAST ILLUMINANTION LEVEL
X
X
NO FLICKER SYSTEM
X
X
NUMBER OF DISINFECTION CYCLES
n/a
3
PROGRAMMING OF DISINFECTION CYCLES
n/a
X
WI-FI CONNECTION
n/a
X
MAXIMUM DISINFECTANT EFFICACY**
n/a
99.5
PHOTOBIOLOGICAL EN 62471 RISK LEVEL
0
2
  • The technical data reported, unless otherwise indicated, refer to the sunlight mode and represent typical values subject to tolerance.
  • RED Regulations directive 2014/53/EU


** Departement of Molecualr and Developmental Medicine: EVALUATION OF VIRUCIDE ACTIVITY AGAINST SARS-COV-2 OF nUVA CEILING LAMP BY FARO – TEST ON nUVA-A CEILING LAMP BY FARO.

TECHNOLOGY INNOVATION AND WELLBEING

TM-30 is a metric introduced by CIE to even more reliably express colour rendition and hence the quality of a LED source.

TM-30 is a metric introduced by CIE (International Commission on Illumination) in their Technical Report 224:2017 to even more reliably express colour rendition and hence the quality of a LED source.

The correct light balance thanks to the perfect synchronism of 3 light sources: the operating light, the pre-operative light and the solar spectrum ceiling light.

FARO LIGHT SYSTEM

Wellness and safety in a single ceiling light